Saturday, September 11, 2010

US Department of Energy wants 20% power by wind by 2030

This is an example of the magnitude of the problem with wind power.

http://www.windpoweringamerica.gov/pdfs/20_percent_wind_2.pdf

This report wants the US to achieve 20% of their power by wind within the next 20 years. This is a similar goal for Ontario, though our size is obviously smaller, the scale of the ramp up would be relatively the same.

The goal is to have 230gigawatts of power by wind. What is interesting is the report does not note the number of turbines needed, nor the costs. It's simple enough to do.

The current output is 11.4gigawatts of capacity. Understand that capacity is not physical output, it's name plate. Turbines operate at less than 18% name plate 50% of the time.

To achieve that 230gW from the current 11.4gW would require a growth rate of construction of 16%. Now compare that to the US economy barely at 1% right now, 3% before the recession.

But this is the numbers:


Year

GW

1.5mW turbines per year

@18% name plate

3mW turbines per year

@18% name plate

1.5mW per day

3mW per day

@ $3million for each 1.5mW

2008

11.4

7,600

41,800

3,800

20,900

115

57

$ 125,400,000,000

2009

13.2

8,816

48,488

4,408

24,244

133

66

$ 145,464,000,000

2010

15.3

10,227

56,246

5,113

28,123

154

77

$ 168,738,240,000

2011

17.8

11,863

65,245

5,931

32,623

179

89

$ 195,736,358,400

2012

20.6

13,761

75,685

6,880

37,842

207

104

$ 227,054,175,744

2013

23.9

15,963

87,794

7,981

43,897

241

120

$ 263,382,843,863

2014

27.8

18,517

101,841

9,258

50,921

279

140

$ 305,524,098,881

2015

32.2

21,479

118,136

10,740

59,068

324

162

$ 354,407,954,702

2016

37.4

24,916

137,038

12,458

68,519

375

188

$ 411,113,227,454

2017

43.4

28,903

158,964

14,451

79,482

436

218

$ 476,891,343,847

2018

50.3

33,527

184,398

16,763

92,199

505

253

$ 553,193,958,863

2019

58.3

38,891

213,902

19,446

106,951

586

293

$ 641,704,992,281

2020

67.7

45,114

248,126

22,557

124,063

680

340

$ 744,377,791,046

2021

78.5

52,332

287,826

26,166

143,913

789

394

$ 863,478,237,613

2022

91.1

60,705

333,878

30,353

166,939

915

457

$ 1,001,634,755,631

2023

105.6

70,418

387,299

35,209

193,649

1,061

531

$ 1,161,896,316,532

2024

122.5

81,685

449,267

40,842

224,633

1,231

615

$ 1,347,799,727,177

2025

142.1

94,754

521,149

47,377

260,575

1,428

714

$ 1,563,447,683,525

2026

164.9

109,915

604,533

54,958

302,267

1,656

828

$ 1,813,599,312,890

2027

191.3

127,502

701,258

63,751

350,629

1,921

961

$ 2,103,775,202,952

2028

221.9

147,902

813,460

73,951

406,730

2,229

1,114

$ 2,440,379,235,424

2029

257.3

171,566

943,613

85,783

471,807

2,585

1,293

$ 2,830,839,913,092

2030

298.5

199,017

1,094,591

99,508

547,296

2,999

1,499

$ 3,283,774,299,187

Total:

1,395,371

7,674,538

697,685

3,837,269

$ 23,023,613,669,104


Note the last line under the number of 1.5mW turbines needed assuming an 18% capacity factor (50% of the time). That's 7.7 MILLION turbines. The per day, look at the year 2030. That's 3000 turbines completed and opperational EVER DAY for that last year. And the total costs at $3M each? That's $23 TRILLION!

So anyone wish to make a bet the US can do this?

Wish to bet we can in Ontario?

Oh, but someone will complain. That 230gW is CAPACITY the US wants. No, they want 20% of their POWER to come from wind, so in fact to get that means a capacify factor that adds up to 230gW. Hence the larger number of turbines. Othewise what's the point of putting all that in place for only 18% of that 20% they are targeting?

Now, add to this these new reports on what is happening in the EU with wind and solar. Read them, you will be very interested in this as this is the path Ontario is on right now.

Wind Energy’s House of Cards
http://www.energytribune.com/articles.cfm/5131/Wind-Energys-House-of-Cards

WIND ENERGY THE CASE OF DENMARK
http://www.cepos.dk/fileadmin/user_upload/Arkiv/PDF/Wind_energy_-_the_case_of_Denmark.pdf

Germany's Solar Cell Promotion: Dark Clouds on the Horizon
http://repec.rwi-essen.de/files/REP_08_040.pdf

Note this at the end:

From a social welfare perspective, we therefore recommend the rapid reduction of
these subsidies, taking account of recent estimates of annual reductions in
production cost, which are on the order of 12% to 15%.

They are recommending the German Government stop their FIT program. Yet we are racing ahead with one.

Global adjustment: a political time bomb in Ontario

http://www.lexology.com/library/detail.aspx?g=c928396d-91c8-4b60-a828-6d05ecc80eae











Canada November 25 2009





Prior to April, 2009, most Ontario electricity consumers probably paid little attention to the "Provincial Benefit" line item on their electricitybills. They had little reason to. Since its inception in 2005, the Provincial Benefit, known in Ontario's electricity industry as the GlobalAdjustment, was a relatively small adjustment on their electricity bills.


A drastic drop in market prices for electricity and increased governmental payment obligations have made this overlooked price adjustment a powder kegof political resentment and consumer backlash. In April 2009, for the first time ever, the Global Adjustment charged to Ontario electricity consumersexceeded the market price of the electricity they purchased. In every month since then the Global Adjustment has been significantly greater than themarket price for electricity purchased by these consumers


The Global Adjustment is the difference between the rates paid by Ontario governmental authorities to regulated and contracted electricity generatorsand the spot market prices for electricity consumed in Ontario. If the amount paid by Ontario governmental authorities for the generation of theelectricity is higher than the market price for the electricity, a positive Global Adjustment is charged to Ontario electricity consumers. If theamount paid by Ontario governmental authorities for the generation of the electricity is lower than the market price for such electricity, a negativeGlobal Adjustment is credited to Ontario electricity consumers.


The amounts paid by Ontario governmental authorities that are factored into the Global Adjustment fall into three categories: (1) amounts payable fornuclear and baseload hydroelectric generation by Ontario Power Generation Inc. (OPG), (2) amounts paid for non-utility generation administered by theOntario Electricity Financial Corporation (OEFC), and (3) amounts paid under agreements between the Ontario Power Authority (OPA) and electricitygenerators and suppliers of conservation services. Each of these three categories of governmental payment is explained in more detail below.


In the case of OPG's regulated hydroelectric and nuclear generators, a fixed price for electricity is set by the OEB. If the net revenue earned fromthe sale of electricity produced by these regulated baseload generators is less than the regulated price, the difference is charged to electricityconsumers as part of the Global Adjustment. If the net revenue from OPG's sale of this electricity is more than the OEB's fixed price, the excess iscredited to consumers.


Non-utility generators (NUGs) are generators that are not owned by the former Ontario Hydro. These generators provide electricity at set prices underpower purchase agreements with what is now the OEFC. As is the case with the OPG base-load regulated generators, the difference between the OEFC's netrevenue from the sale of this electricity and the amount that it pays to the NUGs under power purchase agreements is charged to electricity consumersas a component of the Global Adjustment.


The final component of the Global Adjustment arises under OPA contracts for generation and demand management projects. Some of these projects were setup through the OPA's former "Request for Proposals" process while other projects resulted in power purchase contracts without recourse to the RFPprocess. The OPA provides guaranteed revenue to electricity suppliers under these agreements. If the project earns net revenue that is less than theguaranteed amount, the difference is made up from a charge to the Ontario consumer through the Global Adjustment.


April 2009 saw an unprecedented change in the Global Adjustment. Until then the Global Adjustment had never exceeded 1.44 cents per kWh, and in thevast majority of months it had been less than 1 cent per kWh. In April, 2009 the Global Adjustment shot up to 3.020 cents per kWh and has remainedabove 3 cents per kWh each month since, except for June 2009 when it dipped to the still relatively high amount of 2.79 cents per kWh.


By covering the gap between the market price for electricity consumed in Ontario and the amount Ontario governmental authorities contract to pay out inthe categories outlined above, the Global Adjustment reduces the volatility of electricity prices and passes the cost of new generation projects on toconsumers. This procedure enables the Ontario government to offer price certainty to new generation and demand management projects, spurring thedevelopment of new electricity supply projects in Ontario.


However, consumer resentment may be growing now that reduced economic activity, particularly in Ontario's flagging manufacturing sector, hascontributed to a steep decline in spot market electricity prices. The Global Adjustment has prevented the benefits of low electricity market pricesfrom being passed on to the Ontario consumers, many of whom badly need it, particularly in light of the rising Canadian dollar.


Hardest hit are consumers who signed retail contracts at locked-in prices before the electricity market price crashed. Retail contracts provide theconsumer a fixed price for electricity, subject to the floating Global Adjustment. Consumers that locked into fixed rates under retail contracts beforethe market prices crashed have experienced a double whammy - locked-in fixed rates that exceed the current market price, plus a drastically increasedGlobal Adjustment.


The guaranteed rates being offered by the OPA under its new Feed-In-Tariff program will put continued upward pressure on the Global Adjustment, byproducing a source of new governmentally-guaranteed pricing for electricity generation.


As a result, it appears Ontario electricity consumers are not going to experience relief from high electricity bills in the foreseeable future.







-------------



RW: The Global Adjustment is extra the producers of power get paid by you when demand is low and the spot price is down. Which is the case with this recession. The producers get paid for lost revenue due to lower demand. They get paid to not produce power.

Let me see if I have this right.

Every weekend you travel half a day with the kids to visit grandma. Before you head out you always fill the tank at the local station. But because you have been laid off, or are suffering increases in other costs, you decide to only go every other weekend.

But that poor gas station owner just lost half the money he normally gets from you. So to compensate him for that loss, the government forces you to pay him double on each visit for the gas to fill your tank, in lieu of the gas you would have used in the weekends you missed.

Get the picture now?

This is how the Provincial Benefit (Global Adjustment) has changed:





Data from: http://www.ieso.ca/imoweb/b100/b100_GA.asp

DO NOT SIGN UP WITH RETAILERS!
You will pay about twice for power if you do as it stands now.

Friday, September 10, 2010

Californa Class Action hits Snag -- reality

From:
Energy And Capital
September 6th, 2010

Last year, a group of about 200 people decided to sue Pacific Gas & Electric, claiming that newly-installed smart meters had jacked up their usage.

Considering these new smart meters were being paraded around as the beginning of a major step in smart grid development, stories about faulty meters were not doing PG&E any favors...
But the stubborn California utility maintained that there was nothing wrong with the meters, and that the lawsuit was without merit. Nonetheless, the California Public Utilities Commission brought in a third-party auditor to review the accuracy of the installed meters, and to see if these smart meters had actually caused higher energy bills — which more than 600 consumers claimed.

The results of that audit came in last week.

Turns out that the meters worked just fine, and that higher utility bills were a result of hotter temperatures during the heat wave of 2009.

Friday, September 3, 2010

New Ontario Wind Performance Blog

There is so much one can do with exposing the pathetic nature of wind that I'm going to start either a blog or website. Blogger is not so great with graphics as you have noticed, displaying tables in HTML format here is bizzar and a pain in the butt. So I may be leaning to a website.

So stay tuned, may take a month or two to get the analysis and pages ready.

Vitally important that consumers of power know the truth about these "sustainable" power sources.

Oh, and a curious thing. The IESO website has the hourly data in xml format available on line for downloading of all production from all sources, except solar. There is no available data that I can find on the output from all these FIT programs. I suspect that solar is even worse for power production than wind (certainly on today's cloudy day).

Wednesday, September 1, 2010

WIND PRODUCTION IN ONTARIO

The Liberal Government, through it's Green Energy Act, wants more wind turbines in Ontario, and ramming through as many as it can as fast as it can. When a wind farm is proposed, the wind operator will claim that so many megawatts of capacity are going to be installed.

That number they give is the name plate capacity of all the turbines combined. That is, a 1.5mW turbine has a capacity of 1.5 megaWatts. That's the name plate. But it is a lie to claim that is what the turbines will produce. It gets you thinking that that number, the "capacity" is what they will deliver. They don't want you to know what the real output is.

When pressed, they will claim that the output from wind is 27% of name plate for Ontario, referred to as the "capacity value".

Now what does that mean to you? Do you get the impression that most of the time wind production is 27% of name plate? That most production is around that 27% most of the time? Well, if that is what you think, you are quite wrong, and shows how grossly misleading that 27% is. Again, a tactic to make you think wind power is viable.

In a normal distribution curve, a bell curve, the average is the apex of the top of the bell curve. Thus the average would also be the most number of hours. All values on either side are evenly distributed around that average. That means that the number of hours at 40% name plate would be the same as the number of hours at 14%.

In a normal distribution curve another number is vital to know, and that's the Standard Deviation. The SD is the measure of the width of the bottom of the curve. The smaller the SD the narrower the bottom of the bell, the larger the wider the bottom. The SD is added and subtracted from the average to get the upper and lower standard deviations. 68% of all values fall within the USD and LSD. Values above and below the second Standard Deviation are considered rare. 95% of all values fall inside the second Standard Deviation.

Not once have I ever seen the Standard Deviation mentioned in wind output, even though it is a vital number to know.

There is only one way to find out what is actually going on since the wind industry is unwilling to share the real numbers with the public.

I downloaded the hourly data from 11-apr-2010 to 8-jul-2010 for the entire fleet of wind turbines in Ontario, this is what I get when I plot the number of hours at each percent name plate:



The area under the graph is the total hours within that date range. Notice how the plot is skewed to the lower percents of name plate. That is, more hours wind output is at the lower ends of percent name plate.

Things change if the bell shape is skewed. You can see the graph shows significant skewness. In fact, it is very significant. The skewness of that graph was 1.28. Skewness is zero in a normal distribution. When skewed, the average loses all meaning. The important number on a skewed distribution is the median.

The median is 13% of name plate, half the average. In a skewed graph the Standard Deviation is added and subtracted from the median, not the average. The Standard Deviation is huge, 28%. That means the upper SD is 41% name plate. Thus 68% of all the hourly output numbers are below 41% name plate. The upper second SD is 69%, making any hits above that rare events.

Hence average in a skewed plot is completely meaningless, and not the most number of hours. In fact, only 1.3% of the hours is output at 27%. Thus the capacity factor should not be the average but should be the median, a more physically realistic measure of output.

Since the skewness makes the median almost half the average, then I would suspect that the actual capacity value is not 27% but in fact somewhere between 13 and 15% of name plate.

This is the table of data that gives that graph.

% Name plate

Hours

% of Total

Total Hours: 2136

Accum
% total

0%

30

1.4%

30

1%

1%

48

2.2%

78

4%

2%

49

2.3%

127

6%

3%

61

2.9%

188

9%

4%

48

2.2%

236

11%

5%

75

3.5%

311

15%

6%

69

3.2%

380

18%

7%

77

3.6%

457

21%

8%

76

3.6%

533

25%

9%

61

2.9%

594

28%

10%

72

3.4%

666

31%

11%

53

2.5%

719

34%

12%

70

3.3%

789

37%

13%

59

2.8%

848

40%

14%

66

3.1%

914

43%

15%

54

2.5%

968

45%

16%

54

2.5%

1022

48%

17%

37

1.7%

1059

50%

18%

37

1.7%

1096

51%

19%

36

1.7%

1132

53%

20%

62

2.9%

1194

56%

21%

32

1.5%

1226

57%

22%

40

1.9%

1266

59%

23%

37

1.7%

1303

61%

24%

41

1.9%

1344

63%

25%

41

1.9%

1385

65%

26%

35

1.6%

1420

66%

27%

28

1.3%

1448

68%

28%

29

1.4%

1477

69%

29%

27

1.3%

1504

70%

30%

34

1.6%

1538

72%

31%

26

1.2%

1564

73%

32%

19

0.9%

1583

74%

33%

22

1.0%

1605

75%

34%

27

1.3%

1632

76%

35%

15

0.7%

1647

77%

36%

18

0.8%

1665

78%

37%

19

0.9%

1684

79%

38%

17

0.8%

1701

80%

39%

23

1.1%

1724

81%

40%

18

0.8%

1742

82%

41%

21

1.0%

1763

83%

42%

18

0.8%

1781

83%

43%

17

0.8%

1798

84%

44%

14

0.7%

1812

85%

45%

18

0.8%

1830

86%

46%

16

0.7%

1846

86%

47%

17

0.8%

1863

87%

48%

19

0.9%

1882

88%

49%

16

0.7%

1898

89%

50%

12

0.6%

1910

89%

51%

11

0.5%

1921

90%

52%

12

0.6%

1933

90%

53%

7

0.3%

1940

91%

54%

14

0.7%

1954

91%

55%

14

0.7%

1968

92%

56%

10

0.5%

1978

93%

57%

10

0.5%

1988

93%

58%

11

0.5%

1999

94%

59%

9

0.4%

2008

94%

60%

6

0.3%

2014

94%

61%

10

0.5%

2024

95%

62%

4

0.2%

2028

95%

63%

6

0.3%

2034

95%

64%

6

0.3%

2040

96%

65%

10

0.5%

2050

96%

66%

9

0.4%

2059

96%

67%

7

0.3%

2066

97%

68%

7

0.3%

2073

97%

69%

6

0.3%

2079

97%

70%

5

0.2%

2084

98%

71%

2

0.1%

2086

98%

72%

2

0.1%

2088

98%

73%

5

0.2%

2093

98%

74%

5

0.2%

2098

98%

75%

7

0.3%

2105

99%

76%

2

0.1%

2107

99%

77%

4

0.2%

2111

99%

78%

2

0.1%

2113

99%

79%

3

0.1%

2116

99%

80%

4

0.2%

2120

99%

81%

0

0.0%

2120

99%

82%

2

0.1%

2122

99%

83%

5

0.2%

2127

100%

84%

3

0.1%

2130

100%

85%

2

0.1%

2132

100%

86%

1

0.0%

2133

100%

87%

2

0.1%

2135

100%

88%

1

0.0%

2136

100%

89%

0

0.0%

2136

100%

90%

0

0.0%

2136

100%

91%

0

0.0%

2136

100%

92%

0

0.0%

2136

100%

93%

0

0.0%

2136

100%

94%

0

0.0%

2136

100%

95%

0

0.0%

2136

100%

96%

0

0.0%

2136

100%

97%

0

0.0%

2136

100%

98%

0

0.0%

2136

100%

99%

0

0.0%

2136

100%

100%

0

0.0%

2136

100%


Notice the accumulative percent of hours in the right column. Go to the 50% mark. Then read what the name plate percent is. This means that 50% of the time output is less than 18% of name plate!

So the claim of wind output from capacity is wrong, they never produce at capacity. Wind providers will claim that no source of power produces at 100% name plate. This is true. But guess what? Our nuke plants run at between 94 and 98% name plate, and they do that 24/7. Far cry from the less than 18% fifty percent of the time.

How would you like if your car got mileage at less than 18% of it's rated mileage 50% of the time?
Their fall back number, the capacity value, of 27% is also grossly misleading as well as it does not tell you how many hours the production is at each name plate.

The entire public is badly misinformed, deliberately, by the wind industry. This is basic high school statistics. Those in the industry must know this, or they are incompetent. I doubt they are that. This means the wind industry is deliberately keeping the most important numbers of production from public view. The reason why is simple, it would expose how pathetic wind output really is.

The hourly production with the median, skewness and Standard Deviation is crucial to know, deliberately leaving this out is a deliberate attempt to mislead the public.

And you are paying for that deception in your electrical bills.

Time to put an end to this.